<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.3 20210610//EN" "https://jats.nlm.nih.gov/archiving/1.3/JATS-archivearticle1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">world-journal-of-clinical-cancer-research</journal-id>
      <journal-title-group>
        <journal-title>World Journal of Clinical Cancer Research</journal-title>
      </journal-title-group>
      <issn publication-format="electronic">2831-3275</issn>
      <publisher>
        <publisher-name>Directive Publications</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.52338/wjccr.2024.3965</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Research</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>“Evaluation of advanced dosimetry in transarterial radioembolization of hepatocellular carcinoma with 90 Y microspheres”</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name>
            <surname>Sinai</surname>
            <given-names>Mount</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>York</surname>
            <given-names>New</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2024-05-18">
        <day>18</day>
        <month>05</month>
        <year>2024</year>
      </pub-date>
      <history>
        <date date-type="received" iso-8601-date="2024-04-17">
          <day>17</day>
          <month>04</month>
          <year>2024</year>
        </date>
        <date date-type="accepted" iso-8601-date="2024-04-18">
          <day>18</day>
          <month>04</month>
          <year>2024</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© 2024 The Author(s). Published by Directive Publications.</copyright-statement>
        <copyright-year>2024</copyright-year>
        <copyright-holder>The Author(s)</copyright-holder>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <ali:license_ref>https://creativecommons.org/licenses/by/4.0/</ali:license_ref>
          <license-p>This is an open access article distributed under the terms of the CC BY 4.0 licence (https://creativecommons.org/licenses/by/4.0/).</license-p>
        </license>
      </permissions>
      <self-uri content-type="html" xlink:href="https://directivepublications.org/world-journal-of-clinical-cancer-research/evaluation-of-advanced-dosimetry-in-transarterial-radioembolization-of-hepatocellular-carcinom"/>
      <self-uri content-type="pdf" xlink:href="https://directivepublications.org/pdf/908/evaluation-of-advanced-dosimetry-in-transarterial-radioembolization-of-hepatocellular-carcinoma-with-90-y-microspheres.pdf"/>
      <abstract>
        <p>Objective : The aim of our study was to analyze the relationships between tumor (T) and normal tissue (N) absorbed dose in relation to the clinical outcomes in hepatocellular carcinoma (HCC) patients treated with 90 Y microspheres. Materials and methods : After transarterial radioembolization of HCC with 90 Y microspheres, 62 patients (10 females: 52 males, mean age 68.2±8.2 years) were imaged using a four-ring, time-of-flight (TOF), PET/CT system. Low dose, non-diagnostic CT images from PET/CT were utilized for localization of the 90 Y microspheres and attenuation correction of PET images. Response assessment was conducted using mRECIST criteria on MRI one month post treatment and subsequently every three months after 90 Y treatment. Results : Among 62 patients, mean liver, tumor, and normal tissue doses (mean ± SD) were 51.38±23.32 Gy, 682.60±785.19 Gy and 45.54±21.19 Gy, respectively. Out of these patients, 39 exhibited complete response (CR), 11 showed partial response (PR), 2 had stable disease (SD), and 10 showed progression of the disease (PD). For CR+PR patients the mean T was 824.63±833.10 Gy, whereas for PD patients, the mean T was significantly lower at 205.70±183.22 Gy. The mean liver and normal tissue doses were comparable; for CR+PR patients had liver and normal tissue doses of 51.01±22.55 Gy and 45.18±20.68 Gy, respectively, and for PD patients, these values were 54.34±26.73 Gy and 49.10±22.97 Gy, respectively. Conclusion : Despite not considering the partial volume effect and having a limited number of PD cases, our data indicates a statistically significant lower (P = 0.0001) tumor dose in patients with disease progression compared to those with complete and partial response. These results suggest that post-therapy personalized, and image-based dosimetry provides promising predictive outcomes in 90 Y microsphere radiation therapy for liver cancers.</p>
      </abstract>
      <kwd-group kwd-group-type="author">
        <kwd>90 Y Dosimetry</kwd>
        <kwd>90 Y Microspheres</kwd>
        <kwd>Hepatocellular Carcinoma</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec id="introduction">
      <label>1</label>
      <title>Introduction</title>
      <p>Primary liver cancer is the sixth most common cancer worldwide<sup><xref ref-type="bibr" rid="ref-1">1</xref></sup> and hepatocellular carcinoma (HCC) accounts for approximately 90% of all liver cancers.<sup><xref ref-type="bibr" rid="ref-2">2</xref></sup> Considering the high incidence and poor prognosis of HCC, research on the epidemiology of HCC is an important public health issue. Unfortunately, due to extensive disease or other contraindications only about 20% of patients with HCC are candidates for surgical treatment in the form of resection or transplantation. For the remaining cases of unresectable HCC, there are many alternative treatment options, including thermal radiofrequency (RFA) or microwave ablation, external beam radiation, systematic chemotherapy (e.g., Sorafenib), alcohol injections, transarterial chemoembolization (TACE)<sup><xref ref-type="bibr" rid="ref-3">3</xref>,<xref ref-type="bibr" rid="ref-4">4</xref></sup> , and yttrium-90 (<sup>90</sup> Y) selective internal radiation therapy (SIRT).<sup><xref ref-type="bibr" rid="ref-5">5</xref></sup> SIRT with <sup>90</sup> Y microspheres is an effective and safe option for the treatment of HCC. Recently, there has been a growing interest in the use of SIRT, due to its favorable tumor response and safety profile.<sup><xref ref-type="bibr" rid="ref-6">6</xref></sup> This treatment is based on the fact that tumor vascularization is mainly arterial, as opposed to hepatic vascularization. In addition, the intraarterial injection of <sup>90</sup> Y microspheres, if properly performed, delivers high radiation absorbed doses to the tumor while sparing liver parenchyma. It has been shown that higher tumor doses usually achieve a better response.<sup><xref ref-type="bibr" rid="ref-7">7</xref>,<xref ref-type="bibr" rid="ref-8">8</xref></sup> However, using higher activities to increase the tumor-absorbed dose is limited by the increase in healthy liver or normal tissue absorbed dose. Our aim was to retrospectively study the relationships between tumor (T) and normal tissue (N) absorbed dose in relation to the clinical outcomes in HCC treated with 90Y microspheres.</p>
    </sec>
    <sec id="materials-and-methods">
      <label>2</label>
      <title>Materials and Methods</title>
      <sec id="patient-selection-and-study-design">
        <label>2.1</label>
        <title>Patient selection and study design</title>
        <p>Sixty-two patients (10 females: 52 males, mean age 68.2±8.2 years) with unresectable HCC who underwent SIRT with <sup>90</sup> Y microspheres at our institution from June 2013 to May 2019 were included in our study. Among them, fifty-three patients were treated with TheraSphere ® (glass microspheres; Boston Scientific, Marlborough, MA) and nine with SIR-Sphere ® (resin microspheres; Sirtex Medical, Sydney, Australia). All patients had lung absorbed doses under 30 Gy, negligible lung shunting, (i.e., less than 5%), and no extrahepatic leakage. All patients gave written informed consent for treatment, retrospective analysis of their clinical and imaging data for research purposes, and additional effective dose of 0.7 mSv due to the PET/CT study. The additional dose came from the low-dose CT portion in the PET/CT study used for attenuation correction and delineation of the region-of-interest (ROI). All procedures were performed in accordance with the ethical standards of the institutional and national research committee and the Declaration of Helsinki. Exclusion criteria included a small number of cases according to the mRECIST evaluation, which in this study excluded SD cases.</p>
      </sec>
      <sec id="image-acquisition-and-reconstruction-protocols">
        <label>2.2</label>
        <title>Image acquisition and reconstruction protocols</title>
        <p>After SIRT with <sup>90</sup> Y microspheres, patients were imaged on a four-ring, time-of-flight (TOF) PET/CT system Biograph mCT (Siemens Medical Systems, Erlangen, Germany). Only one-bed position acquisitions were used, due to the axial FOV of 216 mm. The acquisition time was 15 min. The reconstruction matrix size was 200 × 200 × 75, and the voxel size was 4.07 × 4.07 × 3.00 mm. Model-based scatter correction method and delayed event subtraction method for randoms correction were used. The low-dose CT, with 120 kV, automatic tube current modulation and slice thickness of 3 mm, was used for PET attenuation correction and localization of the <sup>90</sup> Y microspheres. The iterative 3D Poisson-OSEM algorithm with point spread function and TOF correction was used for the reconstruction of PET data with 2 iterations, 21 subsets (2i21s), and a 5 mm Gaussian post-reconstruction filter.<sup><xref ref-type="bibr" rid="ref-9">9</xref></sup></p>
      </sec>
      <sec id="dosimetry-calculation">
        <label>2.3</label>
        <title>Dosimetry calculation</title>
        <p>A personalized, voxel-based dosimetry method was used to calculate tumor (T), normal tissue (NT), and total liver absorbed doses. The commercially available software package, MIM 7.1 (MIM Software Inc., Cleveland, Ohio), was utilized to calculate post-treatment <sup>90</sup> Y dosimetry from the PET/CT images. For each patient using CT images, volume-of-interest (VOI) for the whole liver and tumor(s) was manually created and a program automatically created a normal tissue VOI. Since, <sup>90</sup> Y decays almost entirely with β- emission (0.93 MeV mean energy, half-life 64.1 h, 2.5 mm mean tissue penetration), the local deposition method, which is a practical alternative to a more complicated dose-point-kernel convolution approach, was used for dosimetry calculations.<sup><xref ref-type="bibr" rid="ref-10">10</xref></sup> <bold>Figure <xref ref-type="fig" rid="figure-1">1</xref></bold> shows a “miss” situation with a low T of 15.77 Gy and N of 43.90 Gy, where the tumor ROI and high <sup>90</sup> Y activity area do not overlap. This was a PD case. On the contrary, in <bold>Figure <xref ref-type="fig" rid="figure-2">2</xref></bold>, a combined PET/CT image shows a “good hit” situation with a high T of 1296.38 Gy and N of 28.58 Gy. The tumor area and relatively high <sup>90</sup> Y activity are nicely correlated. This was a CR case.</p>
        <fig id="figure-1">
          <label>Figure 1</label>
          <caption>
            <p>Progression of disease (PD) case. A “miss” situation with a low T of 15.77 Gy and N of 43.90 Gy, where the tumor ROI and high <sup>90</sup> Y activity area do not overlap.</p>
          </caption>
          <graphic xlink:href="https://directivepublications.org/storage/ftv2/908-96cf45e865afcab49fa5/fig-figure-1.png" mimetype="image" mime-subtype="png"/>
        </fig>
        <fig id="figure-2">
          <label>Figure 2</label>
          <caption>
            <p>Complete response (CR) case. A “good hit” situation with a high T of 1296.38 Gy and N of 28.58 Gy. The tumor area and relatively high <sup>90</sup> Y activity are nicely correlated.</p>
          </caption>
          <graphic xlink:href="https://directivepublications.org/storage/ftv2/908-96cf45e865afcab49fa5/fig-figure-2.png" mimetype="image" mime-subtype="png"/>
        </fig>
      </sec>
      <sec id="statistical-analyses">
        <label>2.4</label>
        <title>Statistical analyses</title>
        <p>Variables were reported as mean ± SD and/or as percentages. Statistical analysis was performed using MedCalc Software, 22.009–64 bit version.<sup><xref ref-type="bibr" rid="ref-11">11</xref></sup> Welch’s t-test, or unequal variances t-test was used for statistical analysis due to the unequal sample size of variables and unequal sample distribution variance. p-values less than 0.05 were considered significant.</p>
      </sec>
      <sec id="doseresponse-evaluation">
        <label>2.5</label>
        <title>Dose–Response Evaluation</title>
        <p>One month post treatment and subsequently every three months after <sup>90</sup> Y treatment, mRECIST criteria done on MRI were used to assess response.</p>
      </sec>
    </sec>
    <sec id="results">
      <label>3</label>
      <title>Results</title>
      <p>For 62 patients, the mean liver, tumor and normal tissue doses (mean ± SD) were 51.38±23.32 Gy, 682.60±785.19 Gy and 45.54±21.19 Gy respectively. Among these patients, 39 showed complete response (CR), 11 showed partial response (PR), 2 showed stable disease (SD), and 10 showed progression of the disease (PD). The overall response rate (ORR), defined as the proportion of patients who have a complete or partial response (CR+PR) to therapy, was 81%. For these patients the mean T was 824.63±833.10 Gy, and for patients with PD, the mean T was significantly lower at 205.70±183.22 Gy. The mean liver and normal tissue doses were similar; for CR+PR patients, liver and normal tissue doses were 51.01±22.55 Gy and 45.18±20.68 Gy, respectively, and for PD patients, the same values were 54.34±26.73 Gy and 49.10±22.97 Gy, respectively. Because we had only two SD cases, they were not considered in this comparison. In <bold>Figure <xref ref-type="fig" rid="figure-3">3</xref></bold>, average tumor doses for CR+PR patients and for PD patients are shown. Welch’s t-test, assuming unequal variances, demonstrated that patients with complete and partial response (CR+PR) had a statistically higher (P = 0.0001) tumor dose than those with progression of the disease.</p>
      <fig id="figure-3">
        <label>Figure 3</label>
        <caption>
          <p>Tumor doses for complete and partial response (CR+PR) patients and for progression of disease (PD) patients. Data shows that patients with complete and partial response (CR+PR) have a statistically higher (P = 0.0001) tumor dose than those with progression of disease.</p>
        </caption>
        <graphic xlink:href="https://directivepublications.org/storage/ftv2/908-96cf45e865afcab49fa5/fig-figure-3.png" mimetype="image" mime-subtype="png"/>
      </fig>
    </sec>
    <sec id="discussion">
      <label>4</label>
      <title>Discussion</title>
      <p>Rather than using semi-quantitative, vendor-designed dosimetry methods, we utilized a personalized dosimetry approach based on quantifiable PET/CT imaging. This method allows for more accurate calculations of liver, tumor, and normal tissue dosimetry than those obtained using predictive <sup>99m</sup> Tc-MAA studies<sup><xref ref-type="bibr" rid="ref-7">7</xref></sup> and/or semi-quantitative dosimetry approaches. Post-therapy quantitative PET/CT images show true <sup>90</sup> Y distribution and provide accurate dosimetry values.</p>
      <p>In any radiotherapy treatment, including <sup>90</sup> Y SIRT of unresectable HCC, one of the main goals is to maximize tumor dose and preserve normal tissue by minimizing its dose. Additionally, in this process, one must deliver at least the recommended tumor mean absorbed dose and keep normal liver tissue below or equal to the safety threshold of the absorbed dose of 40 Gy.<sup><xref ref-type="bibr" rid="ref-12">12</xref></sup> A recent study recommended a 200 Gy threshold for tumor mean absorbed dose<sup><xref ref-type="bibr" rid="ref-13">13</xref></sup> , but higher values would be even more desirable.<sup><xref ref-type="bibr" rid="ref-14">14</xref></sup> The limitation of our approach includes the exclusion of respiratory motion corrections for lesions in the superior hepatic lobes<sup><xref ref-type="bibr" rid="ref-15">15</xref></sup> and the exclusion of partial volume corrections for lesions smaller than 2.5 cm</p>
    </sec>
    <sec id="conclusions">
      <label>5</label>
      <title>Conclusions</title>
      <p>Despite the limited number of PD cases and the exclusion of partial volume effect considerations, our data indicates that patients with complete and partial responses (CR+PR) have a statistically higher (P = 0.0001) tumor dose than those with progression of disease. Further investigation is warranted because we omitted SD cases due to the limited number of cases, preventing any meaningful statistical analysis. Additionally, the total number of all cases should be increased to provide more meaningful results. However, according to our results, we concluded that patients with CR and PR have statistically higher tumor mean absorbed doses than those with progression of disease.</p>
    </sec>
  </body>
  <back>
    <fn-group>
      <title>Competing interests</title>
      <fn id="decl-coi" fn-type="coi-statement">
        <p>None.</p>
      </fn>
    </fn-group>
    <ref-list>
      <title>References</title>
      <ref id="ref-1">
        <label>1</label>
        <mixed-citation>Sung H, Ferlay J, Siegel RL, Laversanne M, Soerjomataram I, Jemal A, et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin. 2021;71:209–249.</mixed-citation>
      </ref>
      <ref id="ref-2">
        <label>2</label>
        <mixed-citation>Villanueva A. Hepatocellular carcinoma. N Engl J Med. 2019;380:1450–1462.</mixed-citation>
      </ref>
      <ref id="ref-3">
        <label>3</label>
        <mixed-citation>Sucandy I, Cheek S, Golas BJ, Tsung A, Geller DA, Marsh JW. Long term survival outcomes of patients undergoing treatment with radiofrequency ablation for hepatocellular carcinoma and metastatic colorectal cancer liver tumors. HPB: Off J Int Hepato Pancreato Biliary Assoc. 2016; 18:756–63. DOI:<pub-id pub-id-type="doi">10.1016/j.hpb.2016.06.010</pub-id>.</mixed-citation>
      </ref>
      <ref id="ref-4">
        <label>4</label>
        <mixed-citation>Lobo L, Yakoub D, Picado O, Ripat C, Pendola F, Sharma R, et al. Unresectable Hepatocellular Carcinoma: Radioembolization Versus Chemoembolization: A Systematic Review and Meta-analysis. Cardiovasc Intervent Radiol. 2016. DOI:<pub-id pub-id-type="doi">10.1007/s00270-016-1426-y</pub-id>.</mixed-citation>
      </ref>
      <ref id="ref-5">
        <label>5</label>
        <mixed-citation>Paprottka PM, Hoffmann RT, Haug A, Sommer WH, Raessler F, Trumm CG, et al. Radioembolization of symptomatic, unresectable neuroendocrine hepatic metastases using yttrium-90 microspheres. Cardiovasc Intervent Radiol. 2012; 35:334–42. DOI:10.1007/ s00270-011-0248-1.</mixed-citation>
      </ref>
      <ref id="ref-6">
        <label>6</label>
        <mixed-citation>Hilgard P, Hamami M, El Fouly A, et al. Hematology.2010;52(5):1741-1749 DOI: <pub-id pub-id-type="doi">10.1002/hep.23944</pub-id> <ext-link ext-link-type="uri" xlink:href="http://onlinelibrary.wiley.com/doi/10.1002/hep.23944/full">http://onlinelibrary.wiley.com/doi/10.1002/hep.23944/full</ext-link></mixed-citation>
      </ref>
      <ref id="ref-7">
        <label>7</label>
        <mixed-citation>Garin E, Tselikas L, Guiu B, et al. Personalized versus standard dosimetry approach of selective internal radiation therapy in patients with locally advanced hepatocellular carcinoma (DOSISPHERE-01): a randomized, multicenter, open label phase 2 trial. Lancet Gastroenterol Hepatol. 2021;6:17–29.</mixed-citation>
      </ref>
      <ref id="ref-8">
        <label>8</label>
        <mixed-citation>Hermann A-L, Dieudonne A, Ronot M, et al. Relationship of tumor radiation-absorbed dose to survival and response in hepatocellular carcinoma treated with transarterial radioembolization with 90 Y in the SARAH study. Radiology. 2020; 296:673–684. https://doi.org/<pub-id pub-id-type="doi">10.1148/radiol.2020191606</pub-id></mixed-citation>
      </ref>
      <ref id="ref-9">
        <label>9</label>
        <mixed-citation>Willowson KP, Tapner M, Bailey DL. QUEST Investigator Team. A multicentre comparison of quantitative Y-90 PET/CT for dosimetric purposes after radioembolization with resin microspheres : The QUEST Phantom Study. Eur J Nucl Med Mol Imaging 2015; 42: 1202–22. doi: https:// doi. org/ 10. 1007/s00259- 015- 3059-9</mixed-citation>
      </ref>
      <ref id="ref-10">
        <label>10</label>
        <mixed-citation>Knešaurek K. Comparison of post-therapy Y-90 PET/CT dosimetry methods in liver therapy with Y-90 microspheres. World J Nucl Med. 19:359-65, 2020. <ext-link ext-link-type="uri" xlink:href="https://www.thieme-connect.com/products/ejournals/pdf/10.4103/wjnm.WJNM_23_20.pdf">https://www.thieme-connect.com/products/ejournals/pdf/10.4103/wjnm.WJNM_23_20.pdf</ext-link></mixed-citation>
      </ref>
      <ref id="ref-11">
        <label>11</label>
        <mixed-citation>MedCalc Statistical Software, version 22.009 (MedCalc Software Ltd, Ostend, Belgium; <ext-link ext-link-type="uri" xlink:href="https://www.medcalc.org">https://www.medcalc.org</ext-link>; 2022)</mixed-citation>
      </ref>
      <ref id="ref-12">
        <label>12</label>
        <mixed-citation>Levillain H, Bagni O, Deroose CM, et al. International recommendations for personalized selective internal radiation therapy of primary and metastatic liver diseases with yttrium-90 resin microspheres. Eur J Nucl Med Mol Imaging 2021; 48: 1570–84. doi: https:// doi. org/ 10. 1007/ s00259- 020-05163-5</mixed-citation>
      </ref>
      <ref id="ref-13">
        <label>13</label>
        <mixed-citation>Roosen J, Klaassen NJM, Westlund Gotby LEL, Overduin CG, Verheij M, Konijnenberg MW, et al. To 1000 Gy and back again a systematic review on dose-response evaluation in selective internal radiation therapy for primary and secondary liver cancer. Eur J Nucl Med Mol Imaging 2021; 48: 3776–90. doi: https:// doi. org/ 10. 1007/s00259- 021- 05340-0</mixed-citation>
      </ref>
      <ref id="ref-14">
        <label>14</label>
        <mixed-citation>Knešaurek K, Martinez RB, Ghesani M. Tumour-to-normal tissue (T/N) dosimetry ratios role in assessment of 90Y selective internal radiation therapy (SIRT). Br J Radiol 2021; 94: 20210294. https:// doi. org/ 10. 1259/ bjr. 20210294</mixed-citation>
      </ref>
      <ref id="ref-15">
        <label>15</label>
        <mixed-citation>Grimm R, Furst S, Souvatzoglou M, Forman C, Hutter J, Dregely I, et al. Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/ MRI. Med Image Anal 2015; 19: 110–20. doi: https:// doi. org/ 10. 1016/ j. media. 2014. 08. 003</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
